During Preliminary Design Model testing the Army took significant steps to run a controlled test and maintain consistency throughout the process, but the Army did not always follow established testing protocols and, as a result, did not achieve its intended test objective of determining as a basis for awarding contracts which designs met performance requirements.

In the most consequential of the Army’s deviations from testing protocols, the Army testers incorrectly measured the amount of force absorbed by the plate designs by measuring back-face deformation in the clay backing at the point of aim rather than at the deepest point of depression.

The graphic depicts the difference between the point of aim and the deepest point.

GAO Body Armor Test Explanation

[NB: So, there it is -- GAO is telling the Congress that after two and one-half years, Army testing failed, and failed so abysmally that $121 Million in protective plates already produced and in warehouses awaiting distribution were designated unsafe to issue because their qualifying tests were unreliable.]

Army testers recognized the error after completing about a third of the test and then changed the test plan to call for measuring at the point of aim and likewise issued a modification to the contract solicitation. [NB: Yes, you read this sentence correctly. After having the error pointed out to them, Army test officials decided the “fix” was to change the test plan/requirements so that this flaw would be consistent throughout all testing!!]

At least two of the eight designs that passed Preliminary Design Model testing and were awarded contracts would have failed if measurements had been made to the deepest point of depression. The deviations from the testing protocols were the result of Aberdeen Test Center’s incorrectly interpreting the testing protocols. In all these cases of deviations from the testing protocols, the Aberdeen Test Center’s implemented procedures were not reviewed or approved by the Army and Department of Defense officials responsible for approving the testing protocols. After concerns were raised regarding the Preliminary Design Model testing, the decision was made not to field any of the plate designs awarded contracts until after First Article Testing was conducted.

During First Article Testing, the Army addressed some of the problems identified during Preliminary Design Model testing, but GAO observed instances in which Army testers did not follow the established testing protocols and did not maintain internal controls over the integrity and reliability of data, raising questions as to whether the Army met its First Article Test objective of determining whether each of the contracted designs met performance requirements. The following are examples of deviations from testing protocols and other issues that GAO observed:

  • The clay backing placed behind the plates during ballistics testing was not always calibrated in accordance with testing protocols and was exposed to rain on one day, potentially impacting test results.
  • Testers improperly rounded down back-face deformation measurements, which is not authorized in the established testing protocols and which resulted in two designs passing First Article Testing that otherwise would have failed. Army officials said rounding is a common practice; however, one private test facility that rounds told GAO that they round up, not down.

[NB: So, a private test facility rounds BFD up, benefiting the soldier while the U.S. Army rounds BFD down, benefiting whom? If you guessed "contractors," you got it right. Yet, the Army and the Pentagon continue to chant their mantra: force protection is our number one priority... force protection is our number one priority. True, combat is inherently dangerous and unpredictable -- but adding risks and hazards by issuing sub-standard protective gear grounds this mantra into a hollow and empty phrase.  Especially if you allow this chant to accompany media reports of a fallen warrior's funeral at Arlington National Cemetery or upon arrival of a flag-draped coffin at Dover AFB -- "force protection is our number one priority...".  It is simply an outrage that in the second decade of the 21st Century, American grunts still get the short straw when it comes to personal protective equipment?]

  • Testers used a new instrument to measure back-face deformation without adequately certifying that the instrument could function correctly and in conformance with established testing protocols. The impact of this issue on test results is uncertain, but it could call into question the reliability and accuracy of the measurements.
  • Testers deviated from the established testing protocols in one instance by improperly scoring a complete penetration as a partial penetration. As a result, one design passed First Article Testing that would have otherwise failed.

With respect to internal control issues, the Army did not consistently maintain adequate internal controls to ensure the integrity and reliability of test data. In one example, during ballistic testing, data were lost, and testing had to be repeated because an official accidentally pressed the delete button and software controls were not in place to protect the integrity of test data. Army officials acknowledged that before GAO’s review they were unaware of the specific internal control problems we identified.

As a result of the deviations from testing protocols that GAO observed, four of the five designs that passed First Article Testing and were certified by the Army as ready for full production would have instead failed testing at some point during the process, either during the Preliminary Design Model testing or the subsequent First Article Test. Thus, the overall reliability and repeatability of the test results are uncertain. Although designs passed testing that would not have if the testing protocols were followed, independent ballistics experts have not assessed the impact of the deviations from the testing protocols to determine if the effect of the deviations is sufficient to call into question the ability of those designs to meet requirements.

[NB; This sentence merits VERY close attention. GAO has raised the crucial issue of whether, for this life-or-death equipment, in use by DOD for over ten years, there is a problem with "the ability of those [protective plate] designs to meet requirements,” There is no dispute that in this sample of the five designs tested, four designs actually failed!! Notwithstanding that U.S. Army test officials certified these 4 failed designs as ready for full production.]

Vendors whose designs passed First Article Testing have begun production of plates. The Army has ordered 2,500 sets of plates (at two plates per set) from these vendors to be used for additional ballistics testing and 120,000 sets of plates to be put into inventory to address future requirements. However, to date, none of these designs have been fielded because, according to Army officials, there are adequate numbers of armor plates produced under prior contracts already in the inventory to meet current requirements.

Roger Charles
Editor and Senior Investigative Reporter for SFTT

Review the Report: http://www.gao.gov/new.items/d10119.pdf

I had previously reported that the GAO had found that the Army’s practice of incorrectly rounding down back-face deformations (“BFD”) would have caused two body armor designs that passed First Article Testing to “have failed if the measurements had not been rounded.”   This is just one of many testing anomalies  chronicled in the 110 page GAO report entitled:  Independent Expert Assessment of Army Body Armor Test Results and Procedures Needed Before Fielding.

Not satisfied with the advantage granted contractors by rounding down BFD, the Army and DOT&E team found another blatantly suspect maneuver that placed Soldiers at higher risk while decreasing the risks and costs to contractors.   This  scheme involved the question of where to measure Back-Face Deformation (“BFD”)?  Seems like it’s a non-issue:  Take the measurement at the deepest point of the depression in the clay backing. 

GAO thought so, and said:   “According to original testing protocols, back-face deformation, was to be measured at the deepest point of the depression in the clay backing . . .  According to Army officials, the deeper the back-face deformation measured in the clay backing, the higher the risk of internal injury or death.”  

Not so fast.  The Army and DOT&E team decided that what counted, and what should determine where the measurement of BFD was taken, was the point of aim for the test shot.  They bandied about some convoluted trigonometric gobbledygook involving “plate curvature variances,” degrees of obliquity, and “the reference plane across the diameter of the indentation.” (There’s more, but I will spare the reader. For those so inclined, see pages 16-21 of the GAO report for the Army DOT&E technical bunkum, and the GAO’s devastating rebuttal on pages 78-84.)

GAO makes this additional point:    “Army Research Laboratory and [Department of Justice]-certified laboratories use the benchmark process of measuring back-face deformation at that deepest point, not at the point of aim.”

There is it is:  Both the Army’s own premier research laboratory, and the Department of Justice agency responsible for testing all domestic law enforcement equipment, both require that BFD be measured at the deepest point.

When you add the “Rounding Down” practices previously reported  to the “pick your point of impact” practiced by Army testers, you have test results that are simply a joke.  Unfortunately, for our brave young men and women serving in harm’s way, this is no laughing matter.

For those keeping score:  Contractors – 2   Soldiers – 0

Roger Charles
SFTT Editor

Share a story

Whether you are on active duty or retired, a friend or family member we encourage you to share your story. As proud Americans we salute our heroes and thank you for your courage and sacrifice. We want to hear from you and so do our readers.

Stay informed: latest news and stories

We respect your email privacy

Thank you for signing up! An email will be sent to the address you provided, asking you to confirm your sign up.

News & Announcements

Our Story

photo of a soldierStand For The Troops (“SFTT”) is a 501(c)(3) non-profit Educational Foundation established by the late Col. David H. Hackworth and his wife Eilhys England to insure that our frontline troops have the best available leadership, equipment and training.

In the past four-plus years SFTT'S active campaign has focused on ensuring America's frontline troops get the best available individual protective equipment and combat gear.

Donations and contributions from concerned Americans help fund the SFTT website.

Hackworth Memorial DVD

photo of HackworthIncludes rare footage from Hack's memorial service at Fort Myers Chapel and burial in Arlington National Cemetery.
All donations received from purchasing of The Hackworth Memorial DVD go to Stand For The Troops a 501 (c) 3 non-profit, non-partisan apolitical foundation established by Hack and his wife Eilhys to make sure that America's front-line forces—the kids Hack loved out at the tip of the spear—always have the right training, leadership and equipment to meet their assigned missions and make it home alive and in one piece.

Our Campaigns

  • December 23, 2009: The law firm of Kirkland & Ellis LLP filed the final motion with the Federal Court in Washington, DC in the Freedom of Information Act (“FOIA”) on behalf of the SFTT’s editor for forensic records held by the Department of Defense (“DOD”).
  • October 16, 2009: The Government Accountability Office (“GAO”) issues report to Congress calling for “independent expert assessment of Army body armor test results.” This damning report of US Army body armor test procedures is the outgrowth of a two-year investigative and educational campaign by SFTT to seek fair and impartial test procedures.

Get Involved

  • RSS feed
    Subscribe to our RSS feed
  • YouTube
    Watch our videos
  • Flickr
    See our photos