Posts Tagged ‘kevlar’

In a recent article published on High Performance Composites, it was reported that the “U.S. Army and Marine Corps are conducting final validation testing of the U.S. military’s next-generation — and radically new — combat helmet at the Army Research Laboratory’s Aberdeen Proving Ground in Maryland. Testing on the Enhanced Combat Helmet (ECH), is expected to last 6 to 12 months. The previous-generation Advanced Combat Helmet (ACH) — currently in use by most U.S. combat troops — is made primarily of Kevlar and phenolic resin. The ECH will be the first to incorporate thermoplastic resin in its construction. Military sources tell HPC that the ECH comprises a carbon-fiber inner cage overmolded with a preform made from Spectra ultrahigh-molecular-weight polyethylene (UHMWPE), supplied by helmet development partner Honeywell Advanced Fibers and Composites (Colonial Heights, Va.).

“,The ECH involves a change in materials, a change in the manufacturing process and a change in the specifications,’  says Honeywell’s armor industry technical leader Lori Wagner. While the UHMWPE outer hemisphere imparts the energy-absorbing antiballistic behavior, the carbon inner cage is designed to resist deformation, offering better local-impact protection for the wearer. The design reportedly results in a 10 percent improvement in ballistic protection while reducing helmet weight.

“The military is expected to issue production contracts to several manufacturers. The helmet will be made using an out-of-autoclave, automated compression-style press. Automation is expected to reduce the cost of making the ECH by 10 to 15 percent compared to the ACH.”

Given the increased attention placed on Brain Trauma Injuries and combat-related head injuries, it is reassuring to see the application of new technologies to provide our frontline troops with greater protection while simulateously reduced the helmet weight.

In previous news articles for SFTT, I had reported on the rather cavalier (“incompetent”  or ”negligent” might be better words) treatment given to body armor testing by the DOD and the US Army.  When in doubt (and there should be no doubt when lives are at stake!), these body armor testers consistently skewed test results in favor of contractors to the detriment of  soldiers in combat who have no legal alternative than to use “approved” military-issue protective equipment.

For years, SFTT has consistently argued that US Army and DOD test procedures have been compromised by less than impartial testing and these arguments have now been confirmed by the GAO which in October, 2009 issued it’s damning indictment of US Army test procedures  to Congress:  “Independent Expert Assessment of Army Body Armor Test Results and Procedures Needed Before Fielding.”

In yet another example of their flawed test procedures, the GAO reports on how DOD testers interpreted “partial” body armor penetration.    The GAO observed  the penetration of small debris through a plate that the DOD testers had counted as only a partial penetration.  Test protocols require that penalty points be assigned when any fragment of the armor material inbeds in, or passes into, the soft under garment (Kevlar backing) behind the plate.

The GAO observed small fragments from the armor three layers deep inside the Kevlar backing, and noted that this shot should have received 1.5 penalty points, causing the tested body armor to have failed phase two testing (First Article Testing).

DOD testers counted the shot as only a partial penetration, contending because no Kevlar fibers in the backing were broken, it did not meet criteria for being counted as a complete penetration of the plate.   When GAO pointed out that the requirement for broken fibers is consistent with DOD’s approved, written test protocols, they acknowledged that the criterion for broken fibers was “not described in the testing protocols or otherwise documented . . . ”

That’s right.   When GAO pointed out that the written test protocols did not require “broken fibers,” the DOD testers admitted that GAO was right, and still improperly assigned the test shot as only being a “partial penetration”!

And in case you have not already guessed, this blatant denial of DOD’s test protocol was effectively bypassed by DOD testers who effectively wrote their “own test standard protocol.”  This allowed a contractor’s armor to pass Phase 2 Testing when it should have been evaluated as a failure.

The GAO study notes that this armor design was also one of the designs that would have failed had BFD been measured at the deepest point of the depression, rather than at the point of aim, during the Phase One (Preliminary Design Model) tests.

So, this particular contractor essentially required two “waivers” from DOD testers for their product to be given a passing evaluation. Not a problem for the DOD testers; the design got a “pass,” and were it not for the GAO oversight, these plates would have been issued to our frontline troops.

Still keeping score?:  Contractors – 3,  Soldiers – 0.

As a retired military officer, it pains me to see grown men quibbling over body armor test procedures and interpretations of test results.  When the lives of men and women serving our country in hazardous combat zones are at stake, there can be no room for error.  Our heroes deserve better.

Roger Charles
SFTT Editor

Review the GAO Report: http://www.gao.gov/new.items/d10119.pdf

Share a story

Whether you are on active duty or retired, a friend or family member we encourage you to share your story. As proud Americans we salute our heroes and thank you for your courage and sacrifice. We want to hear from you and so do our readers.

Stay informed: latest news and stories

We respect your email privacy

Thank you for signing up! An email will be sent to the address you provided, asking you to confirm your sign up.

News & Announcements

Our Story

photo of a soldierStand For The Troops (“SFTT”) is a 501(c)(3) non-profit Educational Foundation established by the late Col. David H. Hackworth and his wife Eilhys England to insure that our frontline troops have the best available leadership, equipment and training.

In the past four-plus years SFTT'S active campaign has focused on ensuring America's frontline troops get the best available individual protective equipment and combat gear.

Donations and contributions from concerned Americans help fund the SFTT website.

Hackworth Memorial DVD

photo of HackworthIncludes rare footage from Hack's memorial service at Fort Myers Chapel and burial in Arlington National Cemetery.
All donations received from purchasing of The Hackworth Memorial DVD go to Stand For The Troops a 501 (c) 3 non-profit, non-partisan apolitical foundation established by Hack and his wife Eilhys to make sure that America's front-line forces—the kids Hack loved out at the tip of the spear—always have the right training, leadership and equipment to meet their assigned missions and make it home alive and in one piece.

Our Campaigns

  • December 23, 2009: The law firm of Kirkland & Ellis LLP filed the final motion with the Federal Court in Washington, DC in the Freedom of Information Act (“FOIA”) on behalf of the SFTT’s editor for forensic records held by the Department of Defense (“DOD”).
  • October 16, 2009: The Government Accountability Office (“GAO”) issues report to Congress calling for “independent expert assessment of Army body armor test results.” This damning report of US Army body armor test procedures is the outgrowth of a two-year investigative and educational campaign by SFTT to seek fair and impartial test procedures.

Get Involved

  • RSS feed
    Subscribe to our RSS feed
  • YouTube
    Watch our videos
  • Flickr
    See our photos